Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism
|Updated:2026-03-12
|
Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism
Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism
解放军医学杂志(英文版)1993年第3期 页码:259-264
Affiliations:
1. Department of Cardiology Nan fang Hospital
2. First Military Medical University
3. ,Guangzhou,510515
Author bio:
Funds:
DOI:
中图分类号:
纸质出版:1993
Accepted:
Scan QR Code
Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism[J]. 解放军医学杂志(英文版), 1993,(3):259-264.
[1]赖世忠,李崇信,秦建新,许顶立,刘伊丽.Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism[J].Journal of Medical Colleges of PLA,1993(03):259-264.
Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism[J]. 解放军医学杂志(英文版), 1993,(3):259-264.DOI:
[1]赖世忠,李崇信,秦建新,许顶立,刘伊丽.Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism[J].Journal of Medical Colleges of PLA,1993(03):259-264.DOI:
Diagnostic value of the abnormal systolic blood pressure recovery ratio in patients with coronary artery disease and its mechanism
摘要
Abstract
<正> To evaluate the diagnostic value of the abnormal systolic blood pressure (SBP) re-covery ratio of exercise test and its mechanisms
142 patients with suspectable angina pectorisunderwent coronary angiography and treadmill exercise test.The SBP recovery ratios at the1st
3rd
and 6th min of the recovery period in patients with coronary artery disease (CAD)were significant higher than those in the control subjects.Of the hymodynamic variables
car-diac index (CI)
stroke volume index (SI) and ejection fraction (EF) were lower
left ventricu-lar end-diastolic pressure (LVEDP) and systemic vascular resistance (SVR) were higher in pa-tients with abnormal SBP response than in patients with normal SBP response.The sensitivityof abnormal SBP recovery ratio for identifying patients with CAD was 68% and the specificitywas 90%.The false positivity rate of abnormal SBP recovery ratios in 21 patients with hyper-tension without CAD was 38%.These results indicate that an abnormal SBP recovery ratio is auseful index for identifying patients with CAD.When the ST segment response to exercise isnormal or borderline
it can increase the sensitivity and the accuracy of the exercise test.Theabnormal SBP response appears to be due to exercise-induced impairment of left ventricularfunction and increase in systemic vascular resistance.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.