A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine
|Updated:2026-03-12
|
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine
解放军医学杂志(英文版)2010年25卷第2期 页码:75-83
Affiliations:
Author bio:
Funds:
supported by the Shanghai Pharmaceutical Association
DOI:
中图分类号:R730.4;R446.1
纸质出版:2010
Accepted:
Scan QR Code
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine[J]. 解放军医学杂志(英文版), 2010,25(2):75-83.
[1].A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients' urine[J].Journal of Medical Colleges of PLA,2010,25(02):75-83.
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine[J]. 解放军医学杂志(英文版), 2010,25(2):75-83.DOI:
[1].A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients' urine[J].Journal of Medical Colleges of PLA,2010,25(02):75-83.DOI:
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients’ urine
摘要
Abstract
Objective: A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction
the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity
accuracy (recovery from urine)
repeatability (within-day and between-day precision)
specificity
sensitivity
and stability. This SPE-liquid/liquid extraction-RPLC is rapid
simple
accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus
personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.