Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system
|Updated:2026-03-12
|
Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system
Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system
解放军医学杂志(英文版)2013年28卷第2期 页码:100-106
Affiliations:
Division of Equipment,Xinqiao Hospital,Third Military Medical University
Author bio:
Funds:
Supported by the Second Batch of Projects of Army Medical Eleventh Five-Year Plan Research(08G084);Chongqing Key Scientific and Technological Projects(CSTC,2008AC5120)
DOI:
中图分类号:R197.39
纸质出版:2013
Accepted:
Scan QR Code
Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system[J]. 解放军医学杂志(英文版), 2013,28(2):100-106.
[1]WANG Qing,CHONG Yinbao,ZHAO An,LIU Jiuling.Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system[J].Journal of Medical Colleges of PLA,2013,28(02):100-106.
Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system[J]. 解放军医学杂志(英文版), 2013,28(2):100-106.DOI:
[1]WANG Qing,CHONG Yinbao,ZHAO An,LIU Jiuling.Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system[J].Journal of Medical Colleges of PLA,2013,28(02):100-106.DOI:
Design of portable and intelligent infuser device for rapid fluid transfusion based on micro-electro-mechanical system
摘要
Abstract
Objective:A novel portable and intelligent fluid resuscitation infuser is proposed in this paper. It satisfies the demands of long time use in harsh environment
such as traffic accident
natural disaster
battlefield
evacuation
pre-hospital emergency and so on. Methods:Miniature linear motor and liquid blood cartridge compose the pump body. It’s based on the biological impedance method to measure and control
which resolve the disadvantage of traditional infuser device:large power dissipation
big size
AC power supply only and can’t be use in field. The whole device weights 250 gram and sizes as two mobile phone together. Results:Model device experiment shows:six number 7 standard AAA size alkaline batteries will run the pump for approximately 8-10 h at 6 liters per hour; IV bag can be placed at any position of patient
even under the stretcher. Conclusion:It provides accurate and reliable intravenous infusion for first-aid treatment in field